Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Environmental Health and Preventive Medicine ; : 109-109, 2021.
Article in English | WPRIM | ID: wpr-922203

ABSTRACT

BACKGROUND@#For the reason that many studies have been inconclusive on the effect of humidity on respiratory disease, we examined the association between absolute humidity and respiratory disease mortality and quantified the mortality burden due to non-optimal absolute humidity in Guangzhou, China.@*METHODS@#Daily respiratory disease mortality including total 42,440 deaths from 1 February 2013 to 31 December 2018 and meteorological data of the same period in Guangzhou City were collected. The distributed lag non-linear model was used to determine the optimal absolute humidity of death and discuss their non-linear lagged effects. Attributable fraction and population attributable mortality were calculated based on the optimal absolute humidity, defined as the minimum mortality absolute humidity.@*RESULTS@#The association between absolute humidity and total respiratory disease mortality showed an M-shaped non-linear curve. In total, 21.57% (95% CI 14.20 ~ 27.75%) of respiratory disease mortality (9154 deaths) was attributable to non-optimum absolute humidity. The attributable fractions due to high absolute humidity were 13.49% (95% CI 9.56 ~ 16.98%), while mortality burden of low absolute humidity were 8.08% (95% CI 0.89 ~ 13.93%), respectively. Extreme dry and moist absolute humidity accounted for total respiratory disease mortality fraction of 0.87% (95% CI - 0.09 ~ 1.58%) and 0.91% (95% CI 0.25 ~ 1.39%), respectively. There was no significant gender and age difference in the burden of attributable risk due to absolute humidity.@*CONCLUSIONS@#Our study showed that both high and low absolute humidity are responsible for considerable respiratory disease mortality burden, the component attributed to the high absolute humidity effect is greater. Our results may have important implications for the development of public health measures to reduce respiratory disease mortality.


Subject(s)
Humans , China/epidemiology , Cities/epidemiology , Climate , Humidity/adverse effects , Models, Theoretical , Nonlinear Dynamics , Respiratory Tract Diseases/mortality , Sensitivity and Specificity
2.
Journal of Biomedical Engineering ; (6): 352-356, 2014.
Article in Chinese | WPRIM | ID: wpr-290754

ABSTRACT

The compressive strength of the original bone tissue was tested, based on the raw human thigh bone, bovine bone, pig bone and goat bone. The four different bone-like apatites were prepared by calcining the raw bones at 800 degrees C for 8 hours to remove organic components. The comparison of composition and structure of bone-like apatite from different bone sources was carried out with a composition and structure test. The results indicated that the compressive strength of goat bone was similar to that of human thigh bone, reached (135.00 +/- 7.84) MPa; Infrared spectrum (IR), X-ray diffraction (XRD) analysis results showed that the bone-like apatite from goat bone was much closer to the structure and phase composition of bone-like apatite of human bones. Inductively Coupled Plasma (ICP) test results showed that the content of trace elements of bone-like apatite from goat bone was closer to that of apatite of human bone. Energy Dispersive Spectrometer (EDS) results showed that the Ca/P value of bone-like apatite from goat bone was also close to that of human bone, ranged to 1.73 +/- 0.033. Scanning electron microscopy (SEM) patterns indicated that the macrographs of the apatite from human bone and that of goat bone were much similar to each other. Considering all the results above, it could be concluded that the goat bone-like apatite is much similar to that of human bone. It can be used as a potential natural bioceramic material in terms of material properties.


Subject(s)
Animals , Cattle , Humans , Apatites , Chemistry , Biomechanical Phenomena , Bone Substitutes , Chemistry , Bone and Bones , Physiology , Compressive Strength , Goats , Microscopy, Electron, Scanning , Swine , X-Ray Diffraction
SELECTION OF CITATIONS
SEARCH DETAIL